Components that allow bi-directional power flow are a relatively new concept for many engineers. Our webinar, Enabling Bi-Directional Energy Flow Using DC Power Transformers provided attendees with more information about this new approach. We’ve also put together a number of posts with some of the best questions from the webinar, along with presenter Harry Vig’s answers to help you understand the basics of bidirectional power design more clearly. This post focuses on questions on our fixed-ratio DC-DC converters, the Bus Converter Module (BCM) which features isolation, and the Non-Isolated Bus Converter Module (NBM). Both of these power components will step voltages up and down, depending on the direction of current flow.
Yes, you can. The only thing you need to remember is that the BCMs have their isolated controls on the high-voltage side, but if the power is coming from the low-voltage side, it’s going to be applied on the low-voltage side first. There are a couple of ways that you can apply power to the high-voltage side to start the BCM. You can either use a smaller, dedicated boost converter, or we have something that’s more akin to a flyback transformer that just gives it a single kick to get the high-voltage side booted, and then once the converter comes up and starts operating it will stay on. That’s slightly more complicated, but it’s a less expensive solution. Our application note on reverse mode startup has lots more information about how to design this circuit.
We use the terms high-voltage and low-voltage side, because there’s not really a primary and secondary side: it really doesn’t matter if you configure it in a reverse or a normal forward direction. Today, all of the BCMs have controls on the high-voltage side, so they require power on this side to boot up. The NBMs can power up from either the high-voltage or the low-voltage side.
On the DC transformer, it’s automatic. It’s exactly the same as an AC transformer.
You could have a load transient hitting a BCM or NBM at the same time as you have a line transient coming from a completely different source, and the transformer will couple both through at the same time. So there’s effectively no delay.
Related content
Webinar rebroadcast: Enabling Bi-Directional Energy Flow Using DC Power Transformers
Application note: Using BCM® Bus Convertersin High Power Arrays
為 AI 處理器供電 —— 48V 垂直供電重塑行業格局
AI 模型需要巨大的電流,導致傳統多相設計超過 50 相 —— 從而引發空間、散熱和控制方面的限制,Vicor 針對這些問題提供了解決方案
創新的 48V AI 電源架構,兼顧高電流密度與高電流增益
Vicor 48V 分比式電源架構大幅降低了熱損耗並提供高電流密度,滿足 AI 處理器的極端功率需求
為 AI 供電,48V 分比式電源架構™大幅降低熱損耗,效能優於多相方案
AI 硬體面臨著嚴峻的功率與散熱限制。 工程師們對 48V 與 6V 中間母線以及新的垂直供電(VPD)結構進行討論
Betterfrost:精準加熱,高效除冰
Betterfrost 使用 48V 模組進行脈衝傳導玻璃加熱,可在 80 秒內去除冰層,同時將啟動除霜能量降低 95%